IBM Data and AI Ideas Portal for Customers


Shape the future of IBM!

We invite you to shape the future of IBM, including product roadmaps, by submitting ideas that matter to you the most. Here's how it works:

Post your ideas

Post ideas and requests to enhance a product or service. Take a look at ideas others have posted and upvote them if they matter to you,

  1. Post an idea

  2. Upvote ideas that matter most to you

  3. Get feedback from the IBM team to refine your idea

Help IBM prioritize your ideas and requests

The IBM team may need your help to refine the ideas so they may ask for more information or feedback. The product management team will then decide if they can begin working on your idea. If they can start during the next development cycle, they will put the idea on the priority list. Each team at IBM works on a different schedule, where some ideas can be implemented right away, others may be placed on a different schedule.

Receive notification on the decision

Some ideas can be implemented at IBM, while others may not fit within the development plans for the product. In either case, the team will let you know as soon as possible. In some cases, we may be able to find alternatives for ideas which cannot be implemented in a reasonable time.

Additional Information

To view our roadmaps: http://ibm.biz/Data-and-AI-Roadmaps

Reminder: This is not the place to submit defects or support needs, please use normal support channel for these cases

IBM Employees:

The correct URL for entering your ideas is: https://hybridcloudunit-internal.ideas.aha.io


ADD A NEW IDEA

FILTER BY CATEGORY

Db2 Utilities Suite for z/OS

Showing 36

MODIFY with DELETEDS and DSN not cataloged printing message as ERROR... and completing with RC4. Should be WARNING instead of ERROR.

Reviewing the output, it is concerning seeing a message with ERROR in the text. DSNU1323I ERROR DELETING IMAGE COPY DATA SET FOR object-type.object-qualifier.object-name DSNUM part-number DSN=dataset-name This is not an ERROR but a fact of...
over 1 year ago in Db2 Utilities Suite for z/OS 0 Not under consideration

FORCE for LOAD

We are currently depending on vendor software that has the capability of cancelling DB2 threads when entering the switch phase of a load. This capability has saved the application team hundreds of incident tickets nightly as they perform loads d...
over 1 year ago in Db2 Utilities Suite for z/OS 1 Delivered

Improve DSNACCOX procedure and DISPLAY command to provide correct information

This idea is a result of case TS002735466 and is being opened as recommended by IBM Support. Currently, there is an undocumented limit of the internal buffers which are managed by DB2 and which are used when processing DISPLAY DB command. When it...
almost 2 years ago in Db2 Utilities Suite for z/OS 1 Delivered

LOAD REPLACE inline copy does not have a PIT_RBA value therefore does not create a valid recovery point

This was reported in Case:TS002919261, text included in next section. All customers using LOAD REPLACE inline copy. This is a gap in the Utility process.
almost 2 years ago in Db2 Utilities Suite for z/OS 0 Planned for future release

Allow REPAIR CATALOG on indexes to reset version numbers

Allow REPAIR CATALOG on indexes to reset version numbers In Db2 Cloning Tool, index version mismatches cause indexes to be rebuilt on the target rather than using the physical copy. Some of these indexes are very large. Corrective ...
almost 2 years ago in Db2 Utilities Suite for z/OS 1 Delivered

LOAD with OVERRIDE for Columns with GENERATED ALWAYS FOR EACH ROW ON UPDATE AS ROW CHANGE TIMESTAMP

we use partitioned tables which must be new structured from time to time. But we have to put all the old data in the new structure. But with column mentioned ( GENERATED ALWAYS FOR EACH ROW ON UPDATE AS ROW CHANGE TIMESTAMP ) it is not possib...
almost 2 years ago in Db2 Utilities Suite for z/OS 1 Delivered

IBM Load - if load column has bad data, Load discards the record instead of Loading the record with a Default value

While converting from BMC Load Plus to the IBM Load, the following anomaly has been identified: The BMC Load parameter DEFAULTIF ERROR does not exist in IBM Load. This causes BMC to load the default value for the column whenever it encounters bad ...
about 2 years ago in Db2 Utilities Suite for z/OS 1 Delivered

Limit the number of tape drives allocated when using a TEMPLATE with STACK NO specified

In our reorg utilities against lobs using inline image copy it is required to use STACK NO, however, since we image copy to tape it causes the DB2 utility to acquire multiple tape drive units all at once for each partition of a UTS. This is an iss...
about 2 years ago in Db2 Utilities Suite for z/OS 2 Delivered

Eliminate Reorgs failing with S513 & IEC146I 513-04 when reorging LOBs

The cause of the S513 error is due to the DB2 reorg utility trying to write two image copies in parallel (one for BASE and one for LOB) when a BASE UTS with LOB TS is being REORG’d and the specified template for image copy datasets has the STACK Y...
about 2 years ago in Db2 Utilities Suite for z/OS 3 Not under consideration

IBM Unload doesn't support parameter AT LOCAL for UTC Timestamp columns

In a SELECT statement the parameter AT LOCAL is supported, for example: SELECTDCOLLID ,-- =' ' --CHAR(18)DNAME ,-- =' ' --CHAR(8)TIMESTMP ,...
about 2 years ago in Db2 Utilities Suite for z/OS 0 Not under consideration