Skip to Main Content
IBM Data and AI Ideas Portal for Customers


Shape the future of IBM!

We invite you to shape the future of IBM, including product roadmaps, by submitting ideas that matter to you the most. Here's how it works:

Post your ideas

Post ideas and requests to enhance a product or service. Take a look at ideas others have posted and upvote them if they matter to you,

  1. Post an idea

  2. Upvote ideas that matter most to you

  3. Get feedback from the IBM team to refine your idea

Help IBM prioritize your ideas and requests

The IBM team may need your help to refine the ideas so they may ask for more information or feedback. The product management team will then decide if they can begin working on your idea. If they can start during the next development cycle, they will put the idea on the priority list. Each team at IBM works on a different schedule, where some ideas can be implemented right away, others may be placed on a different schedule.

Receive notification on the decision

Some ideas can be implemented at IBM, while others may not fit within the development plans for the product. In either case, the team will let you know as soon as possible. In some cases, we may be able to find alternatives for ideas which cannot be implemented in a reasonable time.

Additional Information

To view our roadmaps: http://ibm.biz/Data-and-AI-Roadmaps

Reminder: This is not the place to submit defects or support needs, please use normal support channel for these cases

IBM Employees:

The correct URL for entering your ideas is: https://hybridcloudunit-internal.ideas.aha.io


ADD A NEW IDEA

FILTER BY CATEGORY

All ideas

Showing 12738

304 VLDB - Altering Indexes to Change PIECESIZE Not Online

Change the PIECESIZE of indexes puts the index in rebuild pending status. We need the ability to increase the PIECESIZE where index compression alone is not sufficient to scale an index.
about 8 years ago in Db2 for z/OS 1 Not under consideration

Matrix - Cloudera lastest version integration (CDH5.0)

SDMCC has ordered 70 PowerLinux box plus Symphony, GPFS to run big data analytics application, the application was developped at CDH5.0 (MRv2). Symphony MR to integrate with CDH can bring better performance, reliablity to SDMCC.
about 8 years ago in Spectrum Symphony / Product functionality 3 Not under consideration

Would like OPT_SEEK_FACTOR as a session set environment option

In 11.70, a new "seek cost" component for index costing was introduced, the purpose of which was to more accurately reflect the cost for seeking in an index scan (when index is not clustered) for large indexes. OPT_SEEK_FACTOR is an undocumented O...
about 8 years ago in Informix / Informix Server 0 Not under consideration

Enable READ ONLY access to DB2 from Informix using DRDA protocol

This is request for Wal-Mart , we have 100s of Informix gateway manager installed (DRDA) to join quries Informix and DB2 database.
about 8 years ago in Informix / Informix Server 0 Not under consideration

Allow CTEs reuse resultset with in the same query

Currently a CTE is always being resolved by going back to disk. For example, if the same CTE is reused with in the same query, for each time it is used, it is reading from the disk and processing the entire query. So if it is used 5 times with in ...
about 8 years ago in Db2 Analytics Accelerator for z/OS 0 Not under consideration

SQL skeleton for SQLTrace

SQL skelecton for SQLTrace Most of the customers' product system have to run almost 1000 transactions per seconds, it means there are about 86M transactions per day. so there will be to many SQLs would be traced by current SQL trace.so customer ca...
about 8 years ago in Informix / Informix Server 0 Not under consideration

Only in-memory Temp table

Temporary table only cached in the memory, it does not to write into the temp dbspace.Requirement from China mobile (CMCC), CMCC use lots of temp table in the following 2 ways:Create temp table ... with no log; select * from tab into temp tabname ...
about 8 years ago in Informix / Informix Server 1 Future consideration

AQT10050I MAXIMUM_NETEZZA_ROW_LENGTH

When we try to ADD a table on the accelerator we have this message : Stored procedure call "ACCEL_ADD_TABLES"Parameters: Accelerator name: PSAIDAAConnection profile: LOCBBA AQT10050I - An internal error occurred on the 'PSAIDAA' accelerator: An as...
about 8 years ago in Db2 Analytics Accelerator for z/OS 0 Not under consideration

Enhancements To DB2 or IDAA or Cognos to allow Cognos queries to accessing DB2 to be offloaded to IDAA

We are currently in the process of deploying Cognos on z/OS and are using DB2 z/OS as the metadata repository and, for some applications, the targert DBMS for reporting. Some of the SQL being sent to DB2 is fairly CPU intensive and would be a good...
about 8 years ago in Cognos Analytics 0 Future consideration

CSDK C++ API

Please add bigint and bigserial data types to CSDK C++ library
about 8 years ago in Informix / Informix Client Products 0 Not under consideration