Skip to Main Content
IBM Data and AI Ideas Portal for Customers


Shape the future of IBM!

We invite you to shape the future of IBM, including product roadmaps, by submitting ideas that matter to you the most. Here's how it works:

Post your ideas

Post ideas and requests to enhance a product or service. Take a look at ideas others have posted and upvote them if they matter to you,

  1. Post an idea

  2. Upvote ideas that matter most to you

  3. Get feedback from the IBM team to refine your idea

Help IBM prioritize your ideas and requests

The IBM team may need your help to refine the ideas so they may ask for more information or feedback. The product management team will then decide if they can begin working on your idea. If they can start during the next development cycle, they will put the idea on the priority list. Each team at IBM works on a different schedule, where some ideas can be implemented right away, others may be placed on a different schedule.

Receive notification on the decision

Some ideas can be implemented at IBM, while others may not fit within the development plans for the product. In either case, the team will let you know as soon as possible. In some cases, we may be able to find alternatives for ideas which cannot be implemented in a reasonable time.

Additional Information

To view our roadmaps: http://ibm.biz/Data-and-AI-Roadmaps

Reminder: This is not the place to submit defects or support needs, please use normal support channel for these cases

IBM Employees:

The correct URL for entering your ideas is: https://hybridcloudunit-internal.ideas.aha.io


ADD A NEW IDEA

FILTER BY CATEGORY

All ideas

Showing 4934

dynamically allocated 1000000 locks

this message will start to show repeatedly in the online log:dynamically allocated 1000000 locksbut no more info than that - in order to track down the issue, we need to know what session is causing the increase in locks
over 8 years ago in Informix / Informix Server 0 Not under consideration

IWA Fragment Missing

We have the Informix Warehouse Accelerator running on version 11.70FC8 and the accelerator returns zero results if you try to query against a specific fragment that is not loaded into the Accelerator.
over 8 years ago in Informix / Informix Server 1 Not under consideration

Completely drop storage of all data and index partitions with truncate table command

I just truncated 2 huge tables, after "alter table extent size nnnn".. It took a while for the storage to come down to new extent size, but only table partition shrunk. Index partitions was unaffected, still huge.
over 8 years ago in Informix / Informix Server 0 Not under consideration

Request for a parameter in DB2 z/OS equivalent to the parameter IGNOREWARNINGS available in DB2 LUW into db2cli.ini file.

An SQL stmt accessing DB2 z/OS 10.1, via ODBC, receives a code +354; such a code produces an error inside the application.The following is the SQL stmt that reproduces the problem, run via a bach job accessing DB2 via ODBC:printf("DSN8OIVP SQLExec...
over 8 years ago in Db2 for z/OS 1 Not under consideration

Prevent users with CONNECT role to perform "update statistics ... low"

Prevent users with CONNECT role to perform "update statistics ... low" In some customers in GCG, such as Hong Kong HA and CIB found that the user with CONNECT role can perform "update statistics ... low" statement, and that would cause performance...
over 8 years ago in Informix / Informix Server 0 Not under consideration

Need config param to allow user to specify what dbspaces should be used for Mongo collections

Currently (IDS 12.10.FC2X6) when a collection is created in the Informix server the dbspaces used are selected by some automated process. The user has no control where the data or indexes are placed. There should be a config parameter which could ...
over 8 years ago in Informix / Informix Server 0 Not under consideration

PDO_INFORMIX (CSDK > 2.9) do not recognize DBDATE environment variable

We are using Informix 12.10FC2WE (CSDK 4.1) with PHP and PHP is connected to the database by the PDO_INFORMIX Driver, which is based on the ODBC Driver. The Problem is that, the DBDATE environment variable is not recognized so the date values are ...
over 8 years ago in Informix / Informix Client Products 0 Not under consideration

Develop functionality to see amount of logs used per session

Create a functionality to check at any given time the number of logs that are using a session
over 8 years ago in Informix / Informix Server 0 Not under consideration

Add CART to DSN3106I for trappable response

Add a CART token to the DSN3106I message from the DB2 subsystem. This allows the message to be trapped by console automation tools such as NetView pipelines. Without the CART, the automation process/clist will not be able to obtain the appropriate...
over 8 years ago in Db2 for z/OS 1 Not under consideration

New National Language Support data type with variable size greater then 255 bytes.

The current NVARCHAR data type supports maximum of 255 bytes. In case of use UTF-8 it's not sufficient becuase it means to store about 127 UTF-8 characters.
over 8 years ago in Informix / Informix Server 0 Not under consideration