Skip to Main Content
IBM Data Platform Ideas Portal for Customers


This portal is to open public enhancement requests against products and services offered by the IBM Data Platform organization. To view all of your ideas submitted to IBM, create and manage groups of Ideas, or create an idea explicitly set to be either visible by all (public) or visible only to you and IBM (private), use the IBM Unified Ideas Portal (https://ideas.ibm.com).


Shape the future of IBM!

We invite you to shape the future of IBM, including product roadmaps, by submitting ideas that matter to you the most. Here's how it works:


Search existing ideas

Start by searching and reviewing ideas and requests to enhance a product or service. Take a look at ideas others have posted, and add a comment, vote, or subscribe to updates on them if they matter to you. If you can't find what you are looking for,


Post your ideas

Post ideas and requests to enhance a product or service. Take a look at ideas others have posted and upvote them if they matter to you,

  1. Post an idea

  2. Upvote ideas that matter most to you

  3. Get feedback from the IBM team to refine your idea


Specific links you will want to bookmark for future use

Welcome to the IBM Ideas Portal (https://www.ibm.com/ideas) - Use this site to find out additional information and details about the IBM Ideas process and statuses.

IBM Unified Ideas Portal (https://ideas.ibm.com) - Use this site to view all of your ideas, create new ideas for any IBM product, or search for ideas across all of IBM.

ideasibm@us.ibm.com - Use this email to suggest enhancements to the Ideas process or request help from IBM for submitting your Ideas.

IBM Employees should enter Ideas at https://ideas.ibm.com



Status Submitted
Created by Guest
Created on Oct 23, 2026

IDAA Loader: Improve Restartability Through Automatic Cleanup of Failed LOAD Jobs

πŸ’‘ Idea Details

IDAA Loader should provide improved restartability for failed LOAD jobs by supporting automatic or integrated cleanup of incomplete LOAD operations.

Currently, when an IDAA Loader job fails, the previous LOAD operation may require a separate cleanup procedure before the job can be resubmitted. As a result, Operations cannot always simply resubmit the original JCL after correcting the cause of the failure.

Before restarting the LOAD, the team may need to identify the incomplete operation, prepare or locate the appropriate cleanup JCL, execute the cleanup separately, verify its completion, and then resubmit the original Loader job.

This process introduces additional manual steps, increases recovery time, and makes the restart procedure more complex and susceptible to operational errors.

πŸ”Ž Real-Life Scenario and Pain Points

Consider a LOAD job for table SC1.TB1 targeting IDAA group GR1.

If the Loader job fails, the operation may require cleanup before another LOAD can be started for the same table and target environment. Ideally, after the original cause of the failure has been corrected, Operations should be able to resubmit the same JCL and allow the process to recover automatically.

However, integrating the cleanup step into the original JCL is currently difficult because the available cleanup options do not provide all the information required to identify the specific previous LOAD operation that must be cleaned up.

In particular, the IDAA group should be available as a cleanup selection criterion, together with information such as the table name. This would allow the cleanup process to distinguish between operations for the same table in different IDAA groups.

Conceptually, the cleanup request should be able to identify an operation such as:

Clean up the previous incomplete LOAD operation for table SC1.TB1 on IDAA group GR1.

Without sufficient selection criteria, an automated cleanup step may not be able to identify the correct previous operation safely and unambiguously.

The current process creates the following pain points:

  • ⚠️ Operations cannot simply resubmit the failed Loader job.

  • ⚠️ A separate cleanup job may need to be prepared and executed manually.

  • ⚠️ Recovery requires additional operational knowledge and intervention.

  • ⚠️ The correct incomplete LOAD operation must be identified before cleanup.

  • ⚠️ Recovery time increases because cleanup and resubmission are separate activities.

  • ⚠️ Manual cleanup introduces a risk of selecting the wrong table, LOAD operation, or IDAA target.

  • ⚠️ The procedure becomes more difficult to automate within a standard JCL workflow.

πŸ› οΈ Current Workaround

The current workaround is to perform the recovery in separate steps:

  1. Identify the failed or incomplete IDAA Loader operation.

  2. Determine the table and corresponding IDAA target.

  3. Prepare or update a separate cleanup job.

  4. Execute the cleanup job.

  5. Verify that the cleanup completed successfully.

  6. Resubmit the original Loader job.

Another possible workaround is to include a cleanup step at the beginning of the original JCL. However, this approach is limited because the cleanup process does not currently provide all the selection criteria needed to identify the previous LOAD operation precisely.

In our scenario, the missing information includes the IDAA group, which is required to distinguish the cleanup target when the same table may be associated with different groups or target environments.

βœ… Proposed Solution

We propose that IDAA Loader provide integrated and configurable cleanup capabilities for failed LOAD operations, improving the restartability of Loader jobs.

Two complementary approaches could be supported:

πŸ”„ Option 1: Cleanup Before Execution

IDAA Loader should provide a cleanup function that can be included as a step at the beginning of the JCL.

Before starting a new LOAD, this step would check whether a previous incomplete operation exists for the specified table and IDAA group. If one is found, the Loader would clean it up before continuing with the new execution.

The cleanup function should support selection criteria such as:

  • Table schema

  • Table name

  • IDAA group

  • Accelerator or target environment, when applicable

  • Previous job or LOAD operation identifier, when available

The expected flow would be:

  1. Identify the table and IDAA group specified in the JCL.

  2. Check for an incomplete previous LOAD operation.

  3. Clean up the incomplete operation if one exists.

  4. Return a successful or informational condition code if no cleanup is required.

  5. Continue with the new LOAD execution.

This approach would allow Operations to resubmit the original JCL after correcting the cause of the failure, without manually executing a separate cleanup job.

βš™οΈ Option 2: Cleanup After a Failed Execution

Alternatively, IDAA Loader could provide an option to execute cleanup automatically when a LOAD operation fails.

This behavior should be configurable, allowing customers to determine whether automatic cleanup should occur for all failures or only for specific failure conditions.

The automatic cleanup should:

  • Preserve the messages, logs, and diagnostic information required for problem determination.

  • Clean up only the resources related to the failed operation.

  • Clearly report whether the cleanup completed successfully.

  • Avoid cleanup when manual investigation or recovery is required.

  • Support identification of the operation by table and IDAA group.

  • Return an appropriate condition code indicating both the LOAD failure and the cleanup result.

This approach would leave the environment ready for a new execution immediately after a failed LOAD, whenever automatic cleanup is considered safe.

⭐ Recommended Behavior

Ideally, IDAA Loader should support both approaches through configurable options:

  • Cleanup on failure, to clean up eligible failed operations automatically.

  • Cleanup before restart, to validate and clean up any remaining incomplete operation before starting a new LOAD.

  • Manual cleanup, to remain available for scenarios requiring investigation or explicit administrative control.

Supporting both mechanisms would provide greater flexibility while ensuring that diagnostic information and customer recovery policies are respected.

πŸ“ˆ Benefits and Business Value

This enhancement would:

  • βœ… Allow Operations to resubmit failed Loader jobs using the same JCL.

  • βœ… Reduce the number of manual recovery steps.

  • βœ… Eliminate or reduce the need for separate cleanup jobs.

  • βœ… Shorten recovery time after LOAD failures.

  • βœ… Improve the restartability and operational resilience of IDAA Loader.

  • βœ… Reduce dependency on specialized technical teams during job recovery.

  • βœ… Reduce the risk of cleaning up the wrong LOAD operation or target.

  • βœ… Enable safer automation by identifying the cleanup target using the table and IDAA group.

  • βœ… Simplify the integration of IDAA Loader into automated production workflows.

  • βœ… Improve consistency and standardization of recovery procedures.

  • βœ… Support unattended or minimally supervised Loader executions.

πŸ‘₯ Users Impacted and Frequency

This limitation affects Operations teams, IDAA administrators, Db2 administrators, batch support teams, and application teams that execute or support IDAA Loader jobs.

The impact occurs whenever an IDAA Loader job fails and leaves an incomplete operation that must be cleaned up before the next execution.

Although failures may not occur in every LOAD execution, the recovery procedure is required whenever this condition occurs. In environments with frequent Loader executions, multiple IDAA groups, many tables, or automated batch processing, the accumulated operational impact can be significant.

Each occurrence may require manual identification, cleanup, validation, and resubmission. Improved restartability would therefore provide value across all IDAA Loader workloads by making failed executions easier, faster, and safer to recover.

Needed By Not sure -- Just thought it was cool