IBM Data and AI Ideas Portal for Customers


Shape the future of IBM!

We invite you to shape the future of IBM, including product roadmaps, by submitting ideas that matter to you the most. Here's how it works:

Post your ideas

Post ideas and requests to enhance a product or service. Take a look at ideas others have posted and upvote them if they matter to you,

  1. Post an idea

  2. Upvote ideas that matter most to you

  3. Get feedback from the IBM team to refine your idea

Help IBM prioritize your ideas and requests

The IBM team may need your help to refine the ideas so they may ask for more information or feedback. The product management team will then decide if they can begin working on your idea. If they can start during the next development cycle, they will put the idea on the priority list. Each team at IBM works on a different schedule, where some ideas can be implemented right away, others may be placed on a different schedule.

Receive notification on the decision

Some ideas can be implemented at IBM, while others may not fit within the development plans for the product. In either case, the team will let you know as soon as possible. In some cases, we may be able to find alternatives for ideas which cannot be implemented in a reasonable time.

Additional Information

To view our roadmaps: http://ibm.biz/Data-and-AI-Roadmaps

Reminder: This is not the place to submit defects or support needs, please use normal support channel for these cases

IBM Employees:

The correct URL for entering your ideas is: https://hybridcloudunit-internal.ideas.aha.io


Status Delivered
Created by Guest
Created on Mar 19, 2021

Identify target IDAA name from DISPLAY STATS(LOGREADERTASKS) command

DISPLAY STATS(LOGREADERTASKS) command provides details about log reader tasks.

https://www.ibm.com/support/knowledgecenter/SSEPEK_12.0.0/comref/src/tpc/db2z_cmd_displaystats.html


As seen in the following example if there are multiple Log reader tasks from the same db2, it is not possible to identify the target idaa from the sessionID. However this is required to identify the target IDAA's name for both diagnosing and monitoring purposes. It will be also useful for Data Gate as well if there are multiple targets from the same Db2z subsystem.



12.31.38 STC00116 DSNT788I -SSID

SESSIONID STATUS CURR. POSITION NUM RECS AGE

---------------- ---------- -------------------- ---------- ------

553E982796560801 READING 0000000000018898F400 32071 89s

553EDAC3E7842E02 SUSP EOS 00000000000188CA2280 30 6s

******* DISPLAY OF STATS TERMINATED *********************************

12.31.38 STC00116 DSN9022I -DB2A DSNTDSTS 'DISPLAY STATS' NORMAL COMPLETION

Needed by Date May 31, 2021
  • Admin
    Dennis Lukas Mayer
    Oct 14, 2021

    APAR PH40261 - PTF UI77365 has been shipped on 2021/10/06
    -DISPLAY STATS (Db2) documentation is updated.

    https://www.ibm.com/docs/en/db2-for-zos/12?topic=commands-display-stats-db2

15 MERGED

-DISPLAY STATS(LOGREADERTASKS) should have a Data Sharing Group wide option

Merged
In a Db2 Data Sharing Group, with many members, to determine where the Integrated Synchronization log reader task is running you either need to issue the display command on every member or look in the MSTR task joblog for the DSNI090I message. ...
7 months ago in Db2 Analytics Accelerator for z/OS 1 Delivered