Skip to Main Content
IBM Data and AI Ideas Portal for Customers


Shape the future of IBM!

We invite you to shape the future of IBM, including product roadmaps, by submitting ideas that matter to you the most. Here's how it works:

Post your ideas

Post ideas and requests to enhance a product or service. Take a look at ideas others have posted and upvote them if they matter to you,

  1. Post an idea

  2. Upvote ideas that matter most to you

  3. Get feedback from the IBM team to refine your idea

Help IBM prioritize your ideas and requests

The IBM team may need your help to refine the ideas so they may ask for more information or feedback. The product management team will then decide if they can begin working on your idea. If they can start during the next development cycle, they will put the idea on the priority list. Each team at IBM works on a different schedule, where some ideas can be implemented right away, others may be placed on a different schedule.

Receive notification on the decision

Some ideas can be implemented at IBM, while others may not fit within the development plans for the product. In either case, the team will let you know as soon as possible. In some cases, we may be able to find alternatives for ideas which cannot be implemented in a reasonable time.

Additional Information

To view our roadmaps: http://ibm.biz/Data-and-AI-Roadmaps

Reminder: This is not the place to submit defects or support needs, please use normal support channel for these cases

IBM Employees:

The correct URL for entering your ideas is: https://hybridcloudunit-internal.ideas.aha.io


Status Delivered
Workspace Connectivity
Created by Guest
Created on May 1, 2018

Continue to Support Datastage DB2 Connector for DB2 for i v7.3+

Currently the InfoSphere Information Server 11.5 Datastage DB2 Connector doesn't support a supported version of DB2 for i.

Also include support for Surrogate Key Generator Stage for DB2 supports DB2 for i  v7.3+ 

Business Impact for IBM: If DB2 for i v7.3 connectivity is forced to use ODBC connector (vs DB2 connector), that opens a easier migration path to other DBMS'.  If we are able to use the DB2 connector for DB2 for i, we wouldn't have to change datastage jobs if we wanted to switch to the Db2 LUW common SQL engine.  

The Surrogate key stage depends on Connecting with DB2 connect to DB2 for i if database sequence types are used.

------------------------------------------------------------------------

As per  PMR 27476,L6Q,000   DB2 LUW 10.5 (base dbms for info server 11.5) supports DB2 for i version 5 or later according to IBM support and the provided link as of https://www.ibm.com/support/knowledgecenter/en/SSEPGG_10.5.0/com.ibm.db2.luw.qb.client.doc/doc/r0009731.html
 
as per the same PMR  Db2 iSeries 7.3 is compatible with Db2 LUW 11.1
 
https://www.ibm.com/support/knowledgecenter/en/SSEPGG_11.1.0/com.ibm.db2.luw.qb.client.doc/doc/r0009731.html
Db2 Version 11.1 clients can connect to the following midrange and mainframe platforms:
Db2 for z/OS® and OS/390® Version 10 or later
Db2 for IBM i Version V6R1 or later
Db2 for VM and VSE Version 7
 
so the base DB2 LUW product that connects to DB2 for i under the covers for info server DB2 connector stage supports connecting to DB2 for i.. and the next version of DB2 LUW 11.1 too.  So why would info server not continue to support the use of the DB2 connector with the remote DB2 for i database cataloged with DB2 LUW? Especially with the Common SQL engine strategic direction.
-----------------------------
Also IBM Info server datastage support last week with case TS000175311 gave me a link to connect to this page... https://www.ibm.com/developerworks/data/library/techarticle/dm-1305connect/ that says how to connect to DB2 for i with Info server!!! last week!!!!! and that was when they helped me set up the Surrogate Key Generator stage which needs DB2 for i database 
------------------------------------------------------------------------------------------------------------------
in this case it said  ----> Looking at our internal documentation, DB2 connector supports DB2 iSeries 7.1 but not 7.3.
 
 IBM i V7.1 is no longer supported as of 4/30/2018 according to product lifecycle
https://www-01.ibm.com/software/support/lifecycleapp/PLCSearch.wss?q=ibm+i+7.1&ibm-search=Search
 
so therefor the DB2 connector stage doesn't support a supported version of DB2 for i as of 4/30/2018.
------------------------------------------------------------------------------------------------------------------
This case I still have open TS000795643 where the update a row with a db2 connector doesn't work after an IBM i upgrade from 7.1 to 7.3 where it works with another IBM DB2 for i that was upgraded from 7.2 to 7.3.